Autoptic sewage water treatment |
The plant is designed for on-site installation in urban hospitals, hospitals lacking connection to sewerage systems and urban water treatment plants. The disinfection system is particularly dedicated to the wastewater treatment of authoptic rooms. SWT-ASW ensures the mechanical treatment and final chemical disinfection of wastewater without producing potentially infectious sludge and harmful compounds thanks to the use of peracetic acid as disinfectant (sodium hypochlorite or chlorine dioxide can be used as well). The plant is completely automatic and does not require continuous supervision. Staff only needs to carry out checks at predefined times and refill the disinfectant tank.
*Example of layout: PLEASE NOTE that each plant is customized according to projects requirements. Including: feasability study,executive layout, installation, commissioning;
At first the sedimentable solids are removed from the raw wastewater, which is partially clarified before entering the next stages. The tank has a predefined volume in order to obtain the correct hydraulic retention time (HRT). The transferring pump system, under PLC control, modulates the plant flow rate and transfers the wastewater to the separator tank.
In the separation tank the sludge is separated from the water. The sludge is collected in a dedicated bin and the water can pass through a special mesh of 0,25 mm and reach the final disinfection tank.
The third stage consists of a disinfection tank fitted with a special reactor for the multiple injection of the disinfectant and an inner mixing system. The reactor is designed in order to ensure the correct contact time between water and disinfectant. The disinfectant dosing system modulates the dose according to the flow rate of the waste water and the pH value controlled by the PLC.
In case of prolonged inactivity, in order to wash and disinfect the entire plant, a special software can be provided with a timer that controls the opening and closing of valves for the injection of tap water.
Designed for urban hospitals and hospitals lacking connection to sewage systems |
Suitable for autoptic rooms |
Removal of wastewater biological hazards |
On-site installation for authoptic rooms
3 cubic meter of wastewater processed every hour |
Automatic operation |
No harmful compounds produced |
No infections spread of in the environment |
Working 24/7 |